← All films /01 Solar control — metal aluminium · INFLEX Platinum Channel Partner

The workhorse series.

Metallised aluminium solar control film in six VLT points, from near-blackout ML01 to daylight-neutral ML65 — one family that can spec an entire façade. Supplied and installed by Juxtapose across Mumbai, Pune, Bangalore, Hyderabad and Delhi.

VLT 2%

ML01

TSER 88% · SHGC 0.06 · VLT 2 ± 1%

VLT 9%

ML10

TSER 85% · SHGC 0.14 · VLT 9 ± 2%

VLT 17%

ML15

TSER 78% · SHGC 0.23 · VLT 17 ± 2%

VLT 38%

ML40

TSER 63% · SHGC 0.44 · VLT 38 ± 2%

VLT 59%

ML60

TSER 52% · SHGC 0.61 · VLT 59 ± 2%

VLT 66%

ML65

TSER 41% · SHGC 0.71 · VLT 66 ± 2%

/ Choosing within the series

West and south-west elevations carry the heat load — ML01, ML10 and ML15 prioritise TSER and low SHGC where deeper tint is acceptable. ML40 holds the middle. ML60 and ML65 keep daylight-first spaces bright while still shedding infrared.

/ Asked at spec stage
Which ML film for a west-facing façade?

ML01, ML10 or ML15 — the heat-load face wants maximum TSER and low SHGC. ML01 reaches 88% TSER at 2% VLT; ML15 is the usual compromise where the room still needs some view.

What does the number in each ML name mean?

It tracks the nominal visible light transmission — ML10 sits at 9 ± 2% VLT, ML40 at 38 ± 2%, ML65 at 66 ± 2%. Lower number, deeper tint, more heat rejected.

Are these films reflective from outside?

The deeper films are — ML01 reads 89% external reflectance, falling to 11% on ML65. If low reflectance both sides matters, look at the sputtered AS series instead.

What's the glass?

Send orientation, approximate areas and the glass spec if you have it. Estimation comes back with film options and a quote.

Send the brief →