← Home / Heat-control films · INFLEX Platinum Channel Partner

Cut the heat. Keep the view.

Sixteen architectural films across four series — solar control, one-way vision, energy saving and metal sputtering. Specified the way you actually spec: by VLT and SHGC. Supplied and installed by Juxtapose across Mumbai, Pune, Bangalore, Hyderabad and Delhi.

16 films
/01 Solar control — metal aluminium

The workhorse series. Metallised aluminium construction, six VLT points from near-blackout to daylight-neutral — one family that can spec an entire façade.

VLT 2%

ML01

TSER 88% · SHGC 0.06 · VLT 2 ± 1%

VLT 9%

ML10

TSER 85% · SHGC 0.14 · VLT 9 ± 2%

VLT 17%

ML15

TSER 78% · SHGC 0.23 · VLT 17 ± 2%

VLT 38%

ML40

TSER 63% · SHGC 0.44 · VLT 38 ± 2%

VLT 59%

ML60

TSER 52% · SHGC 0.61 · VLT 59 ± 2%

VLT 66%

ML65

TSER 41% · SHGC 0.71 · VLT 66 ± 2%

/02 One-way vision

Daytime privacy without losing the outward view. Reflective exterior face, clear sightline from inside — for street-facing glass, ground-floor offices and meeting rooms on the glass line.

VLT 16%

DS

TSER 80% · SHGC 0.21 · VLT 16 ± 2%

VLT 11%

NS

TSER 83% · SHGC 0.22 · VLT 11 ± 2%

VLT 13%

BS

TSER 81% · SHGC 0.28 · VLT 13 ± 2%

VLT 2%

GS

TSER 88% · SHGC 0.22 · VLT 2 ± 1%

/03 Energy saving

Low interior reflectance and balanced VLT for buildings chasing cooling-load numbers — HVAC relief on large glazed elevations without the mirror-box look.

VLT 13%

ES15

TSER 80% · SHGC 0.37 · VLT 13 ± 2%

VLT 25%

ES25

TSER 67% · SHGC 0.40 · VLT 25 ± 2%

VLT 31%

ES30

TSER 65% · SHGC 0.40 · VLT 31 ± 2%

/04 Metal sputtering

Spectrally selective sputtered coatings — the premium tier. High infrared rejection at higher VLT, low reflectance both sides. For daylight-first architecture that still has to hit thermal targets.

VLT 15%

AS15

TSER 70% · SHGC 0.33 · VLT 15 ± 2%

VLT 35%

AS35

TSER 63% · SHGC 0.42 · VLT 35 ± 2%

VLT 50%

AS50

TSER 51% · SHGC 0.49 · VLT 50 ± 2%

/ Which film for which façade

West & south-west glass

ML01 · ML10 · ML15 · AS15

The heat-load face. Prioritise TSER and low SHGC; accept deeper tint.

Street-facing & ground floor

DS · NS · BS · GS

Daytime privacy with an outward view. Pair with manifestation film where code requires.

Daylight-first architecture

ML60 · ML65 · AS50

Hold the light, still shed infrared. Sputtered AS50 keeps reflectance low both sides.

Cooling-load targets

ES15 · ES25 · ES30

Energy-saving series for HVAC relief on large glazed elevations.
Also on our racks

We supply and install 3M, Hanita and Garware sun-control and heat-control films alongside the INFLEX range — and we'll tell you straight which film fits your spec and budget.

/ Asked at spec stage
Which film cuts the most heat without blacking out the room?

In the INFLEX range, AS15 metal sputtering rejects 80% of infrared at 15% VLT; for maximum total rejection ML01 reaches 88% TSER. For daylight-first spaces, AS50 holds 80% IR rejection at 50% VLT.

What do VLT, SHGC and TSER actually mean?

VLT is the share of visible light the glass still transmits. SHGC is the fraction of solar heat that gets through — lower is cooler. TSER is total solar energy rejected — higher is cooler. Architects typically spec by VLT for appearance and SHGC for thermal performance.

Can these films go on toughened or laminated glass?

Yes — all films in the range are 2-mil interior-applied and suit annealed, toughened and laminated glass. Absorption-heavy films on some IGU configurations need a thermal-stress check; send the glass spec with your enquiry and we confirm suitability.

Do you install, or only supply?

Both. Juxtapose is an INFLEX Platinum Channel Partner and installs with in-house teams across Mumbai, Pune, Bangalore, Hyderabad and Delhi.

Do you also work with 3M, Hanita or Garware films?

Yes — we supply and install 3M, Hanita and Garware sun-control and heat-control films alongside the INFLEX range, and will recommend whichever film fits the spec and budget.

How do I get pricing?

Pricing is per project — it depends on film, glass area, access and city. Send areas and orientation through the enquiry form and estimation responds with a quote.

What's the glass?

Send orientation, approximate areas and the glass spec if you have it. Estimation comes back with film options and a quote.

Send the brief →